    Instruments
    1 888 777-4516
.
       

 

   
 
  J3676S pH/ORP Control Systems
 
   
 
 
 

SYSTEM LOGIC

 


This Model is the ideal system for Monitoring, and Control of pH /ORP. It offers great versatility and finds applications in effluent monitoring of wastewater, process control, pH neutralization etc.  Fully enclosed in a weatherproof enclosure it is suitable for outdoor use or in corrosive environments.

The control logic is simple. From the face panel of the instrument, dial in your set points within which you wish to control the pH/ORP.

 Dual PH/ORP  all contained in one

 NEMA 4X wall mount enclosure


Plug in your chemical feed pumps into the receptacles provided on the bottom of the enclosure. When the pH value rises above the high set point it will activate the acid pump, and lower the pH until it reaches the set point. If the pH falls below the lower set point, the base pump is activated un­til the pH rises to the set point level and then shuts off In this manner, the pH is always maintained within your defined pH levels.

NEMA 4X wall mount enclosure design allows easy mounting. Impact and chemically resistant construction. Transparent front door fastened with a hinged latch and provides a clear view of controller with easy access to front panel adjustments. Bottom access to plug-in receptacles for pumps and BNC electrode connectors provide ease of operation. Operating temperature: -10 to
400 C.
SPECIFICATIONS:


                                                  pH                       mV

Range:                              0 to 14.00 pH     + 1999mV
Resolution:                      0.01 pH                1. Om V
Accuracy: (+1 digit)      + 0.01 pH             + 0.1%
Controller Range:
Relay Output:                  0 to 14.00 pH      + 1999mV
Current Output:              0 to 14.00 pH       0 to 1400 mV
Temp Compensation:          Auto, 0 to 100°C
Temp. Sensor:                  PT -100
Display:                          12.7mm high, LED
Power:                            115 V AC, 1 Phase

 

                                  PROBES

 

Combination electrode

 
Combination electrode for use in process and waste applications. Built for Submersion and In­line applications. The outer body is Ryton and has a 3/4 inch MNPT thread at both ends. An Industrial Plunger style glass electrode is surrounded by a peripheral Porous Teflon liguid junction. This design allows the user to mount the electrode at any angle rather than just vertical as is normal. Comes standard with a 15ft cable and BNC connector. A high temperature version is available for greater than 800C (176F)
Flat Tip Probe  
New Flat Tip pH Probe

No Glass Breakage - Longer Life,  Designed for viscous and heavy suspended solids  

 

   
   
 
  PDS-360 Ultrasonic Open-Channel Flowmeter
   
 
 



PDS-360 Ultrasonic Open-Channel Flowmeter

Featuring :

    6 Months of Daily Flow Totals with Logged Flow Summary
    Time Stamped Data Logging of Average Flow with Event List
    5 Programmable Relays
    Two 4-20 mA Outputs
    Quick, Easy Setup
    High Accuracy
    Non-Contacting

Control Electronics advanced PDS-360 Ultrasonic Open-Channel Flowmeter is a highly accurate, non­contacting liquid flow measuring device. The system is microprocessor controlled and will monitor flows through any flume or weir. Applications range from monitoring flow rates in sewage works to monitoring industrial waste discharge

 

CONTROLLER

Reliable, Accurate, Smart

Precise flow depth measurements are continuously made under processor control. Ultrasonic sound pulses are transmitted from the sensor and elapsed time of echo return is accurately calcu­lated. This information is converted to a depth-of-flow and is applied to the respective equation for the flow device selected. The built-in equations produce a flow rate and totalized flow. 

Proportional analog flow rate signals, relay contact closures and RS-232/485 outputs are available for remote indicating, recording, sampling and Downloading of Flow Data to PC/lapTop. 

Complete solid-state design ensures repeatable, long term, trouble-free operation. All circuits are protected in a NEMA 4X enclosure with a clear polycarbonate hinged cover for easy viewing of flow indications. The controller can be located up to 1500 feet from the measuring site for your convenience.

                                                                      

 
 
pH/ORP Control Systems Metal Immersion Heaters
Open-Channel Flowmeter Liquid Level Controls
Doppler Flowmeter Temperature Controls
Electro-Chemistry Instruments Hand Held pH Meters

 

  CPS-460 Ultrasonic Doppler Flowmeter
   
 
 
  Featuring:
  Detailed Data Logging of Pump Cycles
  31 Day Data Logged Flow Summary
  Exclusive Valve Control Algorithm
  NIST Traceable
  High Accuracy
  Non-Invasive
   
 
  Control Electronics model CPS-460 Ultrasonic Doppler Flowmeter is a highly accurate, noncontacting liquid flow measuring device. The system is microprocessor controlled and will monitor flows of solid-bearing and/or aerated liquids in most standard pipe materials. Applications range from monitoring flow rates in sewage works and industrial waste discharges to controlling valve positioning and pump rates.
 

CONTROLLER   Reliable, Accurate, Smart

Precise Flow measurements are continuously made by an ultrasonic sound wave that penetrates through the pipe wall into the flow stream. Advanced techniques, under processor control, evaluate the returned Doppler signal, eliminating and rejecting unwanted components that may interfere with extraction of the true flow signal. This information is converted to an average flow velocity and is applied to the respective pipe size ID selected. The built-in equations calculate a volume flow rate and total flow. proportional analog flow rate signals, four relay contact closures, RS-232 and modem(opt) outputs are available for remote indicating, recording, sampling, valve control and process control. A detailed Data Logging is also included. All circuits are protected in a NEMA 4X, IP65 enclosure with a clear polycarbonate hinged cover for easy viewing of flow indications. The optional 460R Controller can be located up to 1000 feet from the measuring site.

 

 
   
   
   
 
pH/ORP Control Systems Metal Immersion Heaters
Open-Channel Flowmeter Liquid Level Controls
Doppler Flowmeter Temperature Controls
Electro-Chemistry Instruments Hand Held pH Meters
   
   
  Metal Immersion Heaters
   
 
 

METAL IMMERSION HEATERS
 
  .5 to 54 kW, 35 watts/square inch (5.4 watts/square centimeter) nominal (other sizes and watt densities available). 120, 240, 480 volts standard, 208, 380, 415 and other voltages available.
  Choice of steel, stainless steel (304 and 316) and titanium sheath materials.
   For plating tanks, rinse tanks and other aqueous solutions. Low watt density models available for phosphatizing and concentrated aqueous solutions.
  Single phase standard, three phase available as an option
 

FLUOROPOLYMER (PTFE) HEATERS    
10 Watts Per Square Inch

example: one of many types available
 

 

   
 
pH/ORP Control Systems Metal Immersion Heaters
Open-Channel Flowmeter Liquid Level Controls
Doppler Flowmeter Temperature Controls
Electro-Chemistry Instruments Hand Held pH Meters
   
 

Liquid Level Controls

   
 
 
 
  Product Features and Benefits:
  Remote probe assembly with 10 foot (3 meter) flexible lead. Quick connect plug for easy connection to remote mounted circuitry.
  Stainless steel, titanium, Hastelloy CÒ or graphite probes covered with fluoropolymer resin.
  NEMA 4X equivalent, flame retardant plastic case.
  Field selectable 120/208-240 VAC, 50/60 Hz, 5 watts.
  10 amp, 240 VAC spdt switch capacity.
  70,000 ohm maximum solution resistance
  Longer probe lengths available.
  Operating ambient temperature 0 degrees to 120 degrees Fahrenheit.
  Conductivity style devices operate in most electrically conductive solutions by passing a small AC current between probes.
  Two probe units for single level control.
  Multiple probe units for two point control and refill/pump down capabilities.
  Ideal for plating systems, waste treatment tanks and leak detection.
  Capacitive style available for non contact level control. Mount outside of non metallic tanks with thicknesses up to .984
 
   
 
pH/ORP Control Systems Metal Immersion Heaters
Open-Channel Flowmeter Liquid Level Controls
Doppler Flowmeter Temperature Controls
Electro-Chemistry Instruments Hand Held pH Meters
   
  Temperature Controls
   
 
     
   

 TEMPERATURE DIGITAL CONTROLS

 

  0 degrees to 500 degrees Fahrenheit temperature range standard (field selectable 0 degrees to 260 degrees Celsius).
  Auto-tune PID, PID or On-Off control.
  Provides greater accuracy, safety and energy savings.
  Digital indication of process and set point temperature.
  Large switching capacity available.
  Multiple set points for heat/cool applications available.
  High/Low temperature set points for alarms.
   
     
   
 
pH/ORP Control Systems Metal Immersion Heaters
Open-Channel Flowmeter Liquid Level Controls
Doppler Flowmeter Temperature Controls
Electro-Chemistry Instruments Hand Held pH Meters
   
  Electro-Chemistry Instruments
 
     
     
    Series 200 Electro-Chemistry
 
   
     
   
     
     
   
pH/ORP Control Systems Metal Immersion Heaters
Open-Channel Flowmeter Liquid Level Controls
Doppler Flowmeter Temperature Controls
Electro-Chemistry Instruments Hand Held pH Meters
     
     
  Hand Held pH Meters
   
 
   

Meter with flat surface electrode for fast and easy on-the-spot pH measurements.

   

Features:

  • Built-in Smart chip offers advanced functions and features to a stick style pH meter not found anywhere else
  • RENEW feature that tells you when it’s time to replace your pH electrode
  • CAL feature that tells you when it’s time to recalibrate your meter
  • Flat Surface pH electrode that is completely waterproof and rugged enough to withstand harsh environments
  • Analog bargraph originates at neutral point (pH 7.00) to conveniently view trends in acidity or alkalinity
  • Temperature measurements with Atomatic Temperature Compensation
  • 1, 2 or 3 point calibration automatically recognizes buffer solutions. Order pH buffers separately
  • Complete with flat surface pH electrode, protective sensor cap, sample cup with cap, four 3V CR-2032 button batteries, and 48" (1.2m) neckstrap
   
     
   
     
     
    Home Product Line Waste Water Filter Presses Water Testing Products Agitators /  Mixers Pumps Disposal Containers Filter Systems Tanks Instruments Chemicals Contact Us
     
   
Copyright 2016 Midstates Engineered Equipment  Web Design Crescent Design LLC